{"status":"OK","data":{"advertisement":{"id":377577,"title":"Kompleksowa termomodernizacja budynku produkcyjno-us\u0142ugowego oraz modernizacja systemu ch\u0142odzenia\ntechnologicznego w Kultowym Browarze Staropolskim Sp. z o.o.","partial_offer_allowed":false,"publication_date":"2026-07-17","submission_deadline":"2026-08-10 10:00:00","planned_sign_date":"2026-08-01","supplementary_orders":null,"terms_of_contract_change":null,"created_at":"2026-07-17 13:56:26","modified_at":"2026-08-10 10:00:01","contact_persons":[{"id":5396,"forename":"Marek","surname":"\u0141ycyniak","phone_number":"605888811","email":"marek@browarstaropolski.com","created_by":null,"created_at":"2026-09-28 15:07:07","modified_at":"2026-09-28 15:07:07","modified_by":null}],"orders":[{"id":610276,"estimated_value":"4200000,00","order_items":[{"id":686114,"description":"OPIS PRZEDMIOTU ZAM\u00d3WIENIA\nModernizacja instalacji ch\u0142odniczej budynku Kultowego Browaru Staropolskiego\nZamawiaj\u0105cy\tKultowy Browar Staropolski sp. z o.o.\nAdres obiektu\tul. \u015awi\u0119tego Maksymiliana Marii Kolbego 2, 98-220 Zdu\u0144ska Wola\nPodstawa techniczna\tProjekt przetargowy: Modernizacja instalacji ch\u0142odniczej budynku Kultowego Browaru Staropolskiego, P.P.H.U. MAGIK Piotr Domaga\u0142a, czerwiec 2026\n\n1. Cel zam\u00f3wienia\nCelem zam\u00f3wienia jest wykonanie kompletnej, sprawnej, bezpiecznej i gotowej do eksploatacji instalacji ch\u0142odniczej dla obiektu browaru, zapewniaj\u0105cej wymagane parametry ch\u0142odzenia procesowego i pomieszczeniowego. Instalacja ma umo\u017cliwi\u0107 zast\u0105pienie istniej\u0105cej instalacji amoniakalnej i solankowej instalacj\u0105 zimnego glikolu oraz instalacj\u0105 wody lodowej ze zbiornikiem akumulacji lodu i agregatami wody lodowej.\n2. Dokumenty odniesienia\n\u2022\tProjekt przetargowy - opis techniczny, czerwiec 2026.\n\u2022\tRzuty instalacji ch\u0142odniczej: piwnica -3, parter 0, pi\u0119tro +3, pi\u0119tro +7.\n\u2022\tStrona tytu\u0142owa projektu przetargowego.\n\u2022\tObowi\u0105zuj\u0105ce przepisy prawa, normy bran\u017cowe, DTR producent\u00f3w urz\u0105dze\u0144, wymagania BHP, p.po\u017c., sanitarne i \u015brodowiskowe.\n\u2022\tUzgodnienia dokonane z Zamawiaj\u0105cym na etapie realizacji, o ile nie zmieniaj\u0105 istotnych warunk\u00f3w zam\u00f3wienia.\n3. Podstawowe parametry projektowe\nObszar\tWymaganie / parametr\nMedium instalacji glikolowej\tWodny roztw\u00f3r glikolu propylenowego 35% albo rozwi\u0105zanie r\u00f3wnowa\u017cne dopuszczone przez projektanta i Zamawiaj\u0105cego.\nParametry pracy instalacji glikolowej\ttz/tp = -6/-2\u00b0C, zgodnie z dokumentacj\u0105 projektow\u0105 albo parametry r\u00f3wnowa\u017cne zapewniaj\u0105ce wymagany efekt technologiczny.\nWoda lodowa\tZasilanie odbiornik\u00f3w wskazanych w dokumentacji, w tym wymiennik\u00f3w p\u0142ytowych i p\u0142aszczy ch\u0142odz\u0105cych; temperatura zasilania wg dokumentacji technologicznej.\nAgregaty ch\u0142odnicze\tDwa agregaty ch\u0142odzone powietrzem, ka\u017cdy o wydajno\u015bci ch\u0142odniczej nie mniejszej ni\u017c 300 kW dla warunk\u00f3w projektowych, albo uk\u0142ad r\u00f3wnowa\u017cny zapewniaj\u0105cy wymagan\u0105 moc, redundancj\u0119 i parametry pracy.\nZapotrzebowanie na ch\u0142\u00f3d - glikol\tW dokumentacji przyj\u0119to przewidywane zapotrzebowanie 469 kW i 398,65 kW po wsp\u00f3\u0142czynniku jednoczesno\u015bci 0,85.\nZapotrzebowanie na ch\u0142\u00f3d - woda lodowa\tOdbiorniki obejmuj\u0105 m.in. kadzie fermentacyjne, pasteryzacj\u0119, dealkoholizator, pasteryzator przep\u0142ywowy i wymiennik przy tankofermentorach.\nCi\u015bnienie robocze\tCa\u0142o\u015b\u0107 uk\u0142adu wody lodowej, ruroci\u0105gi, armatura i urz\u0105dzenia - minimum 6 bar, o ile dokumentacja producenta lub projekt nie wymagaj\u0105 wy\u017cszego parametru.\nPr\u00f3ba szczelno\u015bci\tPo monta\u017cu, przed ostatecznym izolowaniem, instalacj\u0119 podda\u0107 p\u0142ukaniu oraz pr\u00f3bie szczelno\u015bci i wytrzyma\u0142o\u015bci na ci\u015bnienie co najmniej 4 bar lub zgodnie z zatwierdzon\u0105 dokumentacj\u0105 wykonawcz\u0105.\n\n4. Zakres rzeczowy wykonawcy\nWykonawca zobowi\u0105zany jest do realizacji kompletnego zakresu niezb\u0119dnego do osi\u0105gni\u0119cia funkcjonalno\u015bci opisanej w dokumentacji. Zakres obejmuje w szczeg\u00f3lno\u015bci:\n4.1. Etap przygotowawczy i dokumentacyjny\n\u2022\tanaliz\u0119 dokumentacji i zg\u0142oszenie ewentualnych kolizji, brak\u00f3w lub rozbie\u017cno\u015bci przed rozpocz\u0119ciem prac;\n\u2022\tsprawdzenie wymiar\u00f3w w naturze oraz weryfikacj\u0119 tras ruroci\u0105g\u00f3w, lokalizacji urz\u0105dze\u0144 i dost\u0119pu serwisowego;\n\u2022\topracowanie dokumentacji wykonawczej, warsztatowej, doborowej oraz kart zatwierdzenia materia\u0142\u00f3w i urz\u0105dze\u0144;\n\u2022\tprzedstawienie bilansu mocy, przep\u0142yw\u00f3w, strat ci\u015bnienia oraz potwierdzenie doboru pomp, agregat\u00f3w, ch\u0142odnic i wymiennik\u00f3w;\n\u2022\tuzgodnienie z Zamawiaj\u0105cym i projektantem zmian technicznych oraz rozwi\u0105za\u0144 r\u00f3wnowa\u017cnych przed ich zastosowaniem.\n4.2. Urz\u0105dzenia i g\u0142\u00f3wne elementy instalacji\n\u2022\tagregaty wody lodowej/ch\u0142odu ch\u0142odzone powietrzem, z kompletnymi szafami zasilaj\u0105co-steruj\u0105cymi, przystosowane do pracy w niskich temperaturach zewn\u0119trznych, zabezpieczeniem przeciwzamro\u017ceniowym i izolacj\u0105 akustyczn\u0105;\n\u2022\tzbiornik buforowy/sprz\u0119g\u0142o hydrauliczne oraz zbiornik akumulacji lodu, je\u017celi wynika z zatwierdzonego rozwi\u0105zania;\n\u2022\tuk\u0142ad pompowy obieg\u00f3w pierwotnych i wt\u00f3rnych, w tym pompy o punktach pracy zgodnych z dokumentacj\u0105 lub r\u00f3wnowa\u017cnych po przeliczeniu hydraulicznym;\n\u2022\tch\u0142odnice powietrza, wymienniki p\u0142ytowe, armatura odcinaj\u0105ca, regulacyjna, r\u00f3wnowa\u017c\u0105ca, bezpiecze\u0144stwa i pomiarowa;\n\u2022\truroci\u0105gi stalowe czarne \u0142\u0105czone przez spawanie albo rozwi\u0105zanie r\u00f3wnowa\u017cne zaakceptowane przez Zamawiaj\u0105cego, z izolacj\u0105 zimnochronn\u0105;\n\u2022\tinstalacj\u0119 odprowadzenia skroplin z ch\u0142odnic powietrza do istniej\u0105cej albo wskazanej instalacji kanalizacyjnej, z syfonowaniem i zabezpieczeniem przed zamarzaniem w miejscach nara\u017conych;\n\u2022\tkompletn\u0105 automatyk\u0119, sterowanie PLC, panel operatorski HMI, czujniki, presostaty, zawory steruj\u0105ce, przemienniki cz\u0119stotliwo\u015bci i okablowanie sterownicze.\n4.3. Roboty monta\u017cowe\n\u2022\ttransport, roz\u0142adunek, wniesienie, posadowienie i monta\u017c urz\u0105dze\u0144;\n\u2022\twykonanie instalacji ruroci\u0105gowych, podwiesze\u0144, podp\u00f3r, przej\u015b\u0107 instalacyjnych, izolacji, oznacze\u0144 i zabezpiecze\u0144 antykorozyjnych;\n\u2022\tkoordynacj\u0119 z czynnym lub modernizowanym zak\u0142adem produkcyjnym, z uwzgl\u0119dnieniem ograniczenia przestoj\u00f3w technologicznych;\n\u2022\tutrzymanie porz\u0105dku, zabezpieczenie miejsca pracy oraz usuni\u0119cie odpad\u00f3w powsta\u0142ych w trakcie rob\u00f3t;\n\u2022\tzabezpieczenie przej\u015b\u0107 przez przegrody wydzielenia po\u017carowego zgodnie z wymagan\u0105 odporno\u015bci\u0105 ogniow\u0105.\n4.4. AKPiA, sterowanie i monitoring\n\u2022\tsterownik PLC realizuj\u0105cy logik\u0119 pracy maszynowni, pomp i odbiornik\u00f3w ch\u0142odu;\n\u2022\tkomunikacj\u0119 z agregatami ch\u0142odniczymi i elementami wykonawczymi;\n\u2022\tsterowanie pompami sieciowymi z wykorzystaniem przemiennik\u00f3w cz\u0119stotliwo\u015bci w celu utrzymywania wymaganej r\u00f3\u017cnicy ci\u015bnie\u0144;\n\u2022\tpanel operatorski HMI z wizualizacj\u0105 podstawowych parametr\u00f3w, alarm\u00f3w, stan\u00f3w pracy i nastaw;\n\u2022\tzabezpieczenia przed prac\u0105 poza zakresem parametr\u00f3w, przed zamarzni\u0119ciem, brakiem przep\u0142ywu, nadmiernym ci\u015bnieniem i awari\u0105 pomp/agregat\u00f3w;\n\u2022\tmo\u017cliwo\u015b\u0107 archiwizacji alarm\u00f3w i podstawowych parametr\u00f3w pracy; opcjonalnie integracj\u0119 z systemem nadrz\u0119dnym, je\u017celi Zamawiaj\u0105cy potwierdzi taki wym\u00f3g.\n4.5. Rozruch, odbiory i szkolenie\n\u2022\tp\u0142ukanie instalacji, pr\u00f3by szczelno\u015bci, pr\u00f3by ci\u015bnieniowe i sporz\u0105dzenie protoko\u0142\u00f3w;\n\u2022\tnape\u0142nienie instalacji w\u0142a\u015bciwym medium i odpowietrzenie uk\u0142adu;\n\u2022\turuchomienie agregat\u00f3w, pomp, ch\u0142odnic, automatyki i zabezpiecze\u0144;\n\u2022\tregulacj\u0119 hydrauliczn\u0105 i potwierdzenie przep\u0142yw\u00f3w oraz parametr\u00f3w temperatury;\n\u2022\trozruch technologiczny w obecno\u015bci Zamawiaj\u0105cego;\n\u2022\tszkolenie personelu Zamawiaj\u0105cego z obs\u0142ugi, bezpiecze\u0144stwa, procedur awaryjnych i podstawowej konserwacji;\n\u2022\tprzekazanie dokumentacji powykonawczej w wersji papierowej i elektronicznej.\n5. Odbiorniki ch\u0142odu i wymagania procesowe\nOdbiornik / obszar\tWymaganie uj\u0119te w dokumentacji lub do potwierdzenia przez wykonawc\u0119\nLe\u017cakownie / piwnice\tCh\u0142odzenie i utrzymanie temperatury pomieszcze\u0144 oraz zbiornik\u00f3w le\u017cakowych; kubatura i liczba zbiornik\u00f3w zgodnie z projektem.\nTankofermentory zewn\u0119trzne\tProcesy sch\u0142adzania, utrzymania i wych\u0142adzania piwa zgodnie z cyklami technologicznymi okre\u015blonymi w projekcie.\nKadzie fermentacyjne - pi\u0119tro i piwnica\tSch\u0142odzenie od +14\u00b0C do +4\u00b0C w 24 h, liczba zbiornik\u00f3w i r\u00f3wnoczesno\u015b\u0107 zgodnie z projektem.\nTanki po\u015brednicz\u0105ce\tUtrzymanie wymaganej temperatury pomieszczenia 4-6\u00b0C i obs\u0142uga zbiornik\u00f3w/p\u0142aszczy ch\u0142odz\u0105cych.\nPasteryzacja i ch\u0142odzenie brzeczki\tObs\u0142uga wymiennik\u00f3w p\u0142ytowych i cykli ch\u0142odzenia wskazanych w projekcie.\nDealkoholizator\tCh\u0142odzenie procesu ci\u0105g\u0142ego; przep\u0142ywy i zapotrzebowanie wymagaj\u0105 weryfikacji doborowej przez wykonawc\u0119.\nWymra\u017cacz z karboblenderem\tSch\u0142odzenie produktu z +8\u00b0C do +2\u00b0C w czasie ok. 1 h; wykonawca potwierdza rzeczywisty bilans zapotrzebowania.\nPropagacja dro\u017cd\u017cy\tCh\u0142odzenie p\u0142aszcza oraz magazynowanie dro\u017cd\u017cy przy wymaganej temperaturze.\nMinibrowar\tPod\u0142\u0105czenie istniej\u0105cego w\u0119z\u0142a zimnego glikolu do nowej instalacji, o ile zakres zostanie utrzymany.\n\n6. Wymagania materia\u0142owe i wykonawcze\n\u2022\truroci\u0105gi, kszta\u0142tki i armatura musz\u0105 by\u0107 dostosowane do medium, temperatury, ci\u015bnienia roboczego oraz warunk\u00f3w eksploatacji;\n\u2022\tuszczelnienia musz\u0105 by\u0107 odporne na wodny roztw\u00f3r glikolu propylenowego;\n\u2022\tizolacja zimnochronna musi by\u0107 paroszczelna; minimalnie 40 mm dla g\u0142\u00f3wnych magistral i 30 mm dla odcink\u00f3w do ch\u0142odnic, chyba \u017ce obliczenia lub DTR wymagaj\u0105 wi\u0119cej;\n\u2022\todcinki nara\u017cone na warunki atmosferyczne nale\u017cy zabezpieczy\u0107 p\u0142aszczem z blachy aluminiowej albo ocynkowanej;\n\u2022\twszystkie elementy stalowe nale\u017cy zabezpieczy\u0107 antykorozyjnie;\n\u2022\todpowietrzniki, manometry i punkty pomiarowe nale\u017cy lokalizowa\u0107 w spos\u00f3b umo\u017cliwiaj\u0105cy obs\u0142ug\u0119 po wykonaniu izolacji;\n\u2022\tnale\u017cy zapewni\u0107 dost\u0119p serwisowy do wszystkich urz\u0105dze\u0144, zawor\u00f3w, filtr\u00f3w, czujnik\u00f3w i element\u00f3w regulacyjnych.\n7. R\u00f3wnowa\u017cno\u015b\u0107 rozwi\u0105za\u0144\nWszelkie nazwy w\u0142asne producent\u00f3w, modeli, system\u00f3w lub materia\u0142\u00f3w wyst\u0119puj\u0105ce w dokumentacji projektowej nale\u017cy traktowa\u0107 jako wskazanie standardu jako\u015bciowego, funkcjonalnego i technicznego. Zamawiaj\u0105cy dopuszcza rozwi\u0105zania r\u00f3wnowa\u017cne, o ile wykonawca wyka\u017ce, \u017ce proponowane rozwi\u0105zanie spe\u0142nia co najmniej wymagania minimalne i nie pogarsza parametr\u00f3w u\u017cytkowych, efektywno\u015bci energetycznej, trwa\u0142o\u015bci, bezpiecze\u0144stwa, akustyki, serwisowalno\u015bci ani mo\u017cliwo\u015bci rozbudowy instalacji.\nParametr r\u00f3wnowa\u017cno\u015bci\tMinimalny spos\u00f3b wykazania\nMoc ch\u0142odnicza\tKarta doborowa dla warunk\u00f3w projektowych, potwierdzaj\u0105ca osi\u0105gni\u0119cie wymaganej mocy.\nParametry temperatury\tPotwierdzenie pracy dla wymaganych temperatur zasilania/powrotu i temperatur zewn\u0119trznych.\nEfektywno\u015b\u0107 energetyczna\tDane producenta: EER, SEER, IPLV lub r\u00f3wnowa\u017cne wska\u017aniki, o ile dost\u0119pne.\nHydraulika\tDob\u00f3r przep\u0142yw\u00f3w, strat ci\u015bnienia, pomp, armatury i \u015brednic.\nAkustyka\tDane o poziomie mocy/ci\u015bnienia akustycznego i zastosowanych zabezpieczeniach.\nAutomatyka\tOpis logiki sterowania, zabezpiecze\u0144, komunikacji i panelu operatorskiego.\nSerwis i cz\u0119\u015bci\tDeklaracja dost\u0119pno\u015bci serwisu i cz\u0119\u015bci zamiennych w okresie gwarancji i co najmniej 5 lat po odbiorze.\n\n8. Gwarancja i serwis\n\u2022\tminimalny okres gwarancji i r\u0119kojmi: 36 miesi\u0119cy od odbioru ko\u0144cowego;\n\u2022\twymagany czas reakcji serwisowej: nie d\u0142u\u017cszy ni\u017c 24 h od zg\u0142oszenia awarii;\n\u2022\twykonawca zapewnia mo\u017cliwo\u015b\u0107 zg\u0142aszan","warranty_period":"minimum 36 miesi\u0119cy","cpv_items":[{"id":5407,"code":"42500000-1","name":"Urz\u0105dzenia ch\u0142odz\u0105ce i wentylacyjne"},{"id":7017,"code":"45310000-3","name":"Roboty instalacyjne elektryczne"},{"id":7076,"code":"45331230-7","name":"Instalowanie urz\u0105dze\u0144 ch\u0142odz\u0105cych"},{"id":7095,"code":"45351000-2","name":"Mechaniczne instalacje in\u017cynieryjne"},{"id":8137,"code":"71320000-7","name":"Us\u0142ugi in\u017cynieryjne w zakresie projektowania"}],"timetable_items":[],"fulfillment_places":[{"country":"Polska","voivodeship":"\u0142\u00f3dzkie","poviat":"zdu\u0144skowolski","commune":"Zdu\u0144ska Wola","locality":"Zdu\u0144ska Wola","created_by":null,"created_at":"2026-07-17 13:56:26","modified_at":"2026-07-17 13:57:02","modified_by":null,"id":781547,"type":{"id":1,"name":"adres"},"group_uuid":"a8a7f6a2-b1a0-4a0d-b280-562ab63088c9"}],"participation_conditions":[{"id":1963233,"description":"Posiadanie wymaganych prawem certyfikat\u00f3w, uprawnie\u0144, autoryzacji lub zapewnienie ich przez personel/podwykonawc\u00f3w w zakresie urz\u0105dze\u0144 ch\u0142odniczych, czynnik\u00f3w ch\u0142odniczych, instalacji elektrycznych i urz\u0105dze\u0144 ci\u015bnieniowych, je\u017celi znajduj\u0105 zastosowanie.","type":{"id":1,"name":"Uprawnienia do wykonywania okre\u015blonej dzia\u0142alno\u015bci lub czynno\u015bci"},"created_by":null,"created_at":"2026-07-17 13:56:26","modified_at":"2026-07-17 13:57:02","modified_by":null,"group_uuid":"4ed883c7-84fb-473f-88dd-8fd0cff5699d"},{"id":1963234,"description":"Wykonanie w okresie ostatnich 5 lat co najmniej dw\u00f3ch instalacji ch\u0142odniczych przemys\u0142owych opartych o glikol, wod\u0119 lodow\u0105 lub rozwi\u0105zania r\u00f3wnowa\u017cne, ka\u017cda o mocy ch\u0142odniczej minimum 300 kW albo o warto\u015bci minimum 1 000 000 PLN netto.","type":{"id":2,"name":"Wiedza i do\u015bwiadczenie"},"created_by":null,"created_at":"2026-07-17 13:56:26","modified_at":"2026-07-17 13:57:02","modified_by":null,"group_uuid":"ca6109ba-abe4-4e97-9b79-5348c6661381"},{"id":1963235,"description":"Dysponowanie osobami zdolnymi do realizacji zam\u00f3wienia, w tym minimum: kierownikiem rob\u00f3t/koordynatorem technicznym, specjalist\u0105 ch\u0142odnictwa, specjalist\u0105 AKPiA oraz osob\u0105 z uprawnieniami elektrycznymi, je\u017celi wykonawca obejmuje zakresem prace elektryczne.","type":{"id":4,"name":"Osoby zdolne do wykonania zam\u00f3wienia"},"created_by":null,"created_at":"2026-07-17 13:56:26","modified_at":"2026-07-17 13:57:02","modified_by":null,"group_uuid":"954708ba-9e79-4b4e-9f06-b3739dfc9b30"},{"id":1963236,"description":"Posiadanie ubezpieczenia OC dzia\u0142alno\u015bci gospodarczej na kwot\u0119 nie ni\u017csz\u0105 ni\u017c 1 000 000 PLN albo zobowi\u0105zanie do jego zawarcia przed podpisaniem umowy","type":{"id":5,"name":"Sytuacja ekonomiczna i finansowa"},"created_by":null,"created_at":"2026-07-17 13:56:26","modified_at":"2026-07-17 13:57:02","modified_by":null,"group_uuid":"bf263ea3-b547-4edb-8e2a-ea839ba60d31"}],"category":{"id":1,"name":"Us\u0142uga"},"subcategory":{"id":8,"name":"Us\u0142ugi inne"},"created_by":null,"created_at":"2026-07-17 13:56:26","modified_at":"2026-07-17 13:57:02","modified_by":null,"group_uuid":"ca2bfa86-b213-4f43-95de-084d1f807c8a"}],"evaluation_criteria":[{"id":1100337,"price_criterion":false,"description":"Cena\t80 pkt\tC = (najni\u017csza cena netto spo\u015br\u00f3d ofert niepodlegaj\u0105cych odrzuceniu / cena netto badanej oferty) x 80 pkt. Je\u017celi VAT jest kosztem kwalifikowalnym lub niepodlegaj\u0105cym odliczeniu, przed publikacj\u0105 nale\u017cy zast\u0105pi\u0107 cen\u0119 netto cen\u0105 brutto.","created_by":null,"created_at":"2026-07-17 13:56:26","modified_at":"2026-07-17 13:57:02","modified_by":null,"group_uuid":"bfbb1ee4-807e-42f0-9801-206e1696d310"},{"id":1100338,"price_criterion":false,"description":"Okres gwarancji i r\u0119kojmi\t10 pkt\tMinimalny wymagany okres: 36 miesi\u0119cy. 36 miesi\u0119cy = 0 pkt; 48 miesi\u0119cy = 5 pkt; 60 miesi\u0119cy i wi\u0119cej = 10 pkt. Okres d\u0142u\u017cszy ni\u017c 60 miesi\u0119cy nie zwi\u0119ksza punktacji.","created_by":null,"created_at":"2026-07-17 13:56:26","modified_at":"2026-07-17 13:57:02","modified_by":null,"group_uuid":"cf3ff7aa-7731-4c77-8213-b4fc7a4dbeca"},{"id":1100339,"price_criterion":false,"description":"Czas reakcji serwisu w okresie gwarancji\t10 pkt\tMaksymalny dopuszczalny czas reakcji: 24 h. Do 24 h = 0 pkt; do 12 h = 5 pkt; do 8 h = 8 pkt; do 4 h = 10 pkt. Reakcja oznacza podj\u0119cie diagnostyki zdalnej lub przyjazd serwisu, zgodnie z charakterem awarii.","created_by":null,"created_at":"2026-07-17 13:56:26","modified_at":"2026-07-17 13:57:02","modified_by":null,"group_uuid":"a2c64202-79bd-44d6-b8b5-52ff2ac7805a"}],"is_variant":false,"title":"Instalacja ch\u0142odnicza","order_node":{"id":460433},"created_by":null,"created_at":"2026-07-17 13:56:26","modified_at":"2026-07-17 13:57:02","modified_by":null}],"created_by":{"id":6092,"contact_persons":[]},"modified_by":{"modified_by":null,"id":1,"contact_persons":[]},"status":{"id":2,"label":"PUBLISHED","name":"Opublikowane"},"advertiser_address_details":{"name":"KULTOWY BROWAR STAROPOLSKI SP\u00d3\u0141KA Z OGRANICZON\u0104 ODPOWIEDZIALNO\u015aCI\u0104","identification_number_type":"nip","identification_number":"6692515194","address":{"country":"Polska","voivodeship":"\u0142\u00f3dzkie","poviat":"zdu\u0144skowolski","commune":"Zdu\u0144ska Wola","locality":"Zdu\u0144ska Wola","created_by":null,"created_at":null,"modified_at":null,"modified_by":null,"id":1067737,"street":"\u015bw. Maksymiliana Marii Kolbego","number_description":"2","postcode":"98-220"},"created_by":{"id":6092,"contact_persons":[]},"created_at":"2026-07-17 13:56:24","modified_at":"2026-07-17 13:56:24","modified_by":{"id":6092,"contact_persons":[]},"id":378590},"advertisement":{"id":285408,"number":"2026-6092-285408","publication_date":"2026-07-17","created_by":{"id":6092,"contact_persons":[]},"created_at":"2026-07-17 13:56:24","modified_at":"2026-08-10 10:00:01","modified_by":{"modified_by":null,"id":1,"contact_persons":[]},"status":{"id":3,"label":"CLOSED","name":"Zamkni\u0119te"},"all_available_version_ids":[377577],"enrollment":null,"projects":[{"id":73491,"name":"Kompleksowa termomodernizacja budynku produkcyjno-us\u0142ugowego oraz modernizacja systemu ch\u0142odzenia technologicznego w Kultowym Browarze Staropolskim Sp. z o.o.","number":"0000/00","activity":{"created_by":{"modified_by":null,"id":89,"contact_persons":[]},"created_at":"2023-02-01 09:26:43","modified_at":"2023-02-01 09:26:43","modified_by":{"modified_by":null,"id":89,"contact_persons":[]}},"region":null,"institution":{"created_by":{"modified_by":null,"id":89,"contact_persons":[]},"created_at":"2023-02-01 09:28:57","modified_at":"2023-02-01 09:28:57","modified_by":{"modified_by":null,"id":89,"contact_persons":[]}},"full_number":"FENG.03.01-IP.03-0000/00","perspective":{},"programme":{"created_by":{"modified_by":null,"id":89,"contact_persons":[]},"created_at":"2023-02-01 09:21:41","modified_at":"2023-02-01 09:21:41","modified_by":{"modified_by":null,"id":89,"contact_persons":[]}},"priority":{"created_by":{"modified_by":null,"id":89,"contact_persons":[]},"created_at":"2023-02-01 09:22:08","modified_at":"2023-02-01 09:22:08","modified_by":{"modified_by":null,"id":89,"contact_persons":[]}},"type":"project","created_by":{"id":6092,"contact_persons":[]},"created_at":"2026-07-17 13:44:50","modified_at":"2026-07-17 13:44:50","modified_by":{"id":6092,"contact_persons":[]}}],"is_author":false,"is_admin":false},"attachments":[{"origin":{"id":377577,"publication_date":"2026-07-17"},"id":2655175,"name":"PP - KBS - Kultowy Browar Staropolski - rzut instalacji - rev00-Parter 0.pdf","file":{"id":2947923,"name":"PP - KBS - Kultowy Browar Staropolski - rzut instalacji - rev00-Parter 0.pdf","created_at":"2026-07-17 13:55:52","created_by":{"forename":"Marek","surname":"\u0141ycyniak"},"uri":"/api/files/2947923"},"group_uuid":"0c2cd3a7-3ad4-4227-a7cd-14f762b3f3af"},{"origin":{"id":377577,"publication_date":"2026-07-17"},"id":2655176,"name":"PP - KBS - Kultowy Browar Staropolski - rzut instalacji - rev00-Pie\u0328tro +3.pdf","file":{"id":2947927,"name":"PP - KBS - Kultowy Browar Staropolski - rzut instalacji - rev00-Pie\u0328tro +3.pdf","created_at":"2026-07-17 13:55:53","created_by":{"forename":"Marek","surname":"\u0141ycyniak"},"uri":"/api/files/2947927"},"group_uuid":"8d60a5ca-9e2e-4d49-b33a-00262e39237a"},{"origin":{"id":377577,"publication_date":"2026-07-17"},"id":2655177,"name":"PP - KBS - Kultowy Browar Staropolski - rzut instalacji - rev00-Pie\u0328tro +7.pdf","file":{"id":2947926,"name":"PP - KBS - Kultowy Browar Staropolski - rzut instalacji - rev00-Pie\u0328tro +7.pdf","created_at":"2026-07-17 13:55:53","created_by":{"forename":"Marek","surname":"\u0141ycyniak"},"uri":"/api/files/2947926"},"group_uuid":"9c475785-617e-487d-b173-19935ed4c795"},{"origin":{"id":377577,"publication_date":"2026-07-17"},"id":2655178,"name":"PP - KBS - Kultowy Browar Staropolski - rzut instalacji - rev00-Piwnica -3.pdf","file":{"id":2947925,"name":"PP - KBS - Kultowy Browar Staropolski - rzut instalacji - rev00-Piwnica -3.pdf","created_at":"2026-07-17 13:55:53","created_by":{"forename":"Marek","surname":"\u0141ycyniak"},"uri":"/api/files/2947925"},"group_uuid":"b214c21f-48b1-414d-85a9-855d52ccc5f6"},{"origin":{"id":377577,"publication_date":"2026-07-17"},"id":2655179,"name":"PP - KBS - Kultowy Browar Staropolski 2026 - opis techniczny.pdf","file":{"id":2947924,"name":"PP - KBS - Kultowy Browar Staropolski 2026 - opis techniczny.pdf","created_at":"2026-07-17 13:55:52","created_by":{"forename":"Marek","surname":"\u0141ycyniak"},"uri":"/api/files/2947924"},"group_uuid":"e5f60330-4ed5-47b7-89d8-221b580aa40b"},{"origin":{"id":377577,"publication_date":"2026-07-17"},"id":2655180,"name":"PP - KBS - Kultowy Browar Staropolski 2026 - strona tytu\u0142owa.pdf","file":{"id":2947922,"name":"PP - KBS - Kultowy Browar Staropolski 2026 - strona tytu\u0142owa.pdf","created_at":"2026-07-17 13:55:52","created_by":{"forename":"Marek","surname":"\u0141ycyniak"},"uri":"/api/files/2947922"},"group_uuid":"b39e00b6-083f-483c-8a7c-ab80b5df62ed"},{"origin":{"id":377577,"publication_date":"2026-07-17"},"id":2655181,"name":"06_Oswiadczenia_i_wykazy_KBS_chlodnia.docx","file":{"id":2947929,"name":"06_Oswiadczenia_i_wykazy_KBS_chlodnia.docx","created_at":"2026-07-17 13:56:07","created_by":{"forename":"Marek","surname":"\u0141ycyniak"},"uri":"/api/files/2947929"},"group_uuid":"78f79519-eb0b-473e-acc3-b37881b663d7"},{"origin":{"id":377577,"publication_date":"2026-07-17"},"id":2655182,"name":"00_Instrukcja_i_spis_pakietu_KBS_chlodnia.docx","file":{"id":2947930,"name":"00_Instrukcja_i_spis_pakietu_KBS_chlodnia.docx","created_at":"2026-07-17 13:56:21","created_by":{"forename":"Marek","surname":"\u0141ycyniak"},"uri":"/api/files/2947930"},"group_uuid":"aa96ab79-b781-4636-9cf0-3743390ba263"},{"origin":{"id":377577,"publication_date":"2026-07-17"},"id":2655183,"name":"01_Zapytanie_ofertowe_KBS_chlodnia.docx","file":{"id":2947934,"name":"01_Zapytanie_ofertowe_KBS_chlodnia.docx","created_at":"2026-07-17 13:56:21","created_by":{"forename":"Marek","surname":"\u0141ycyniak"},"uri":"/api/files/2947934"},"group_uuid":"4b2975c3-66d9-4b0d-a761-232558eecaf0"},{"origin":{"id":377577,"publication_date":"2026-07-17"},"id":2655184,"name":"02_OPZ_KBS_chlodnia.docx","file":{"id":2947935,"name":"02_OPZ_KBS_chlodnia.docx","created_at":"2026-07-17 13:56:22","created_by":{"forename":"Marek","surname":"\u0141ycyniak"},"uri":"/api/files/2947935"},"group_uuid":"6881444e-ed1e-41f9-ac3a-b31d56a5e0ba"},{"origin":{"id":377577,"publication_date":"2026-07-17"},"id":2655185,"name":"03_Formularz_ofertowy_KBS_chlodnia.docx","file":{"id":2947933,"name":"03_Formularz_ofertowy_KBS_chlodnia.docx","created_at":"2026-07-17 13:56:21","created_by":{"forename":"Marek","surname":"\u0141ycyniak"},"uri":"/api/files/2947933"},"group_uuid":"8c64a5a7-2b5f-4f9f-a944-950ec00dadd0"},{"origin":{"id":377577,"publication_date":"2026-07-17"},"id":2655186,"name":"04_Tabela_wyceny_KBS_chlodnia.xlsx","file":{"id":2947932,"name":"04_Tabela_wyceny_KBS_chlodnia.xlsx","created_at":"2026-07-17 13:56:21","created_by":{"forename":"Marek","surname":"\u0141ycyniak"},"uri":"/api/files/2947932"},"group_uuid":"58f9957b-370f-426e-a1cb-e6b558bd45b3"},{"origin":{"id":377577,"publication_date":"2026-07-17"},"id":2655187,"name":"05_Projekt_umowy_KBS_chlodnia.docx","file":{"id":2947931,"name":"05_Projekt_umowy_KBS_chlodnia.docx","created_at":"2026-07-17 13:56:21","created_by":{"forename":"Marek","surname":"\u0141ycyniak"},"uri":"/api/files/2947931"},"group_uuid":"14d14224-5bee-4f8f-b4b9-7f3cfea174c9"}]},"dictionaries":{"announcement_status_draft":1,"announcement_status_published":2},"favorite":null,"badge":null,"offer_set_badge_count":null,"question_badge_count":null}}