{"status":"OK","data":{"advertisement":{"id":373898,"title":"Wykonanie projektu termomodernizacji budynku biurowego zlokalizowanego przy ul. Sokolej 8 w Osielsku","partial_offer_allowed":false,"publication_date":"2026-06-24","submission_deadline":"2026-06-29 23:59:59","planned_sign_date":"2026-06-01","supplementary_orders":null,"terms_of_contract_change":null,"created_at":"2026-06-24 15:55:55","modified_at":"2026-06-30 00:00:24","contact_persons":[{"id":120018,"forename":"\u0141ukasz","surname":"Bernatowicz","phone_number":"","email":"lukasz.bernatowicz@comtex.pl","created_by":null,"created_at":"2026-06-24 15:55:55","modified_at":"2026-06-24 15:55:55","modified_by":null},{"id":120019,"forename":"Artur","surname":"Bernatowicz","phone_number":"601241706","email":"artur.bernatowicz@comtex.pl","created_by":null,"created_at":"2026-06-24 15:55:55","modified_at":"2026-06-24 15:55:55","modified_by":null}],"orders":[{"id":604388,"estimated_value":null,"order_items":[{"id":679722,"description":"Przedmiotem zam\u00f3wienia jest opracowanie kompleksowej dokumentacji projektowej dla przedsi\u0119wzi\u0119cia polegaj\u0105cego na poprawie efektywno\u015bci energetycznej budynku zlokalizowanego w Osielsku (86-031), przy ul. Sokolej 8. Dokumentacja projektowa musi by\u0107 zgodna z audytem energetycznym b\u0119d\u0105cym \nw posiadaniu Zamawiaj\u0105cego oraz zapewnia\u0107 osi\u0105gni\u0119cie wska\u017anik\u00f3w efektywno\u015bci energetycznej okre\u015blonych w audycie oraz we wniosku o dofinansowanie.\nProjekt musi r\u00f3wnie\u017c uwzgl\u0119dnia\u0107 za\u0142o\u017cenia gospodarki o obiegu zamkni\u0119tym oraz zasady 6R, a tak\u017ce wymagania programu FENG, w tym zasad\u0119 DNSH oraz zielonych zam\u00f3wie\u0144.\nZakres opracowania projektowego obejmuje:\n\nA. Termomodernizacj\u0119 budynku:\n\u2022\tocieplenie \u015bcian zewn\u0119trznych z zastosowaniem materia\u0142\u00f3w i technologii zapewniaj\u0105cych osi\u0105gni\u0119cie parametr\u00f3w cieplnych nie gorszych ni\u017c wynikaj\u0105ce z audytu energetycznego oraz obowi\u0105zuj\u0105cych przepis\u00f3w techniczno-budowlanych, w szczeg\u00f3lno\u015bci w zakresie wsp\u00f3\u0142czynnika przenikania ciep\u0142a U,\n\u2022\tocieplenie stropu zewn\u0119trznego (tarasu) z zastosowaniem rozwi\u0105za\u0144 zapewniaj\u0105cych osi\u0105gni\u0119cie parametr\u00f3w energetycznych zgodnych z audytem energetycznym,\n\u2022\tocieplenie stropodachu (dachu \u0142\u0105cznika) z zastosowaniem rozwi\u0105za\u0144 zapewniaj\u0105cych osi\u0105gni\u0119cie parametr\u00f3w energetycznych zgodnych z audytem energetycznym,\n\u2022\tremont dachu sko\u015bnego.\nZamawiaj\u0105cy pozostawia Projektantowi swobod\u0119 doboru technologii oraz materia\u0142\u00f3w, pod warunkiem zachowania parametr\u00f3w technicznych i energetycznych nie gorszych ni\u017c wynikaj\u0105ce z audytu energetycznego oraz obowi\u0105zuj\u0105cych przepis\u00f3w.\n \nB. Wymian\u0119 stolarki okiennej:\n\u2022\tokna zewn\u0119trzne o wsp\u00f3\u0142czynniku przenikania ciep\u0142a min. U \u2264 0,90 W/m\u00b2K, \n\u2022\tokna po\u0142aciowe o wsp\u00f3\u0142czynniku przenikania ciep\u0142a min. U \u2264 1,10 W/m\u00b2K. \n\u2022\tzastosowanie \u017caluzji zewn\u0119trznych od strony po\u0142udniowej budynku, ograniczaj\u0105cych ekspozycj\u0119 pomieszcze\u0144 na promieniowanie s\u0142oneczne oraz wspomagaj\u0105cych ograniczenie zu\u017cycia energii przez system klimatyzacji.\nC. Modernizacj\u0119 systemu grzewczego:\n\u2022\twymiana istniej\u0105cych grzejnik\u00f3w na nowe o podwy\u017cszonej sprawno\u015bci energetycznej - projekt modernizacji powinien przewidywa\u0107 rozwi\u0105zania zapewniaj\u0105ce popraw\u0119 sprawno\u015bci systemu grzewczego, w szczeg\u00f3lno\u015bci w zakresie:\n\u2022\tsprawno\u015bci wytwarzania ciep\u0142a,\n\u2022\tsprawno\u015bci przesy\u0142ania ciep\u0142a,\n\u2022\tsprawno\u015bci regulacji systemu ogrzewczego,\n\u2022\tmo\u017cliwo\u015bci ograniczenia zu\u017cycia energii poprzez wprowadzenie przerw w ogrzewaniu w cyklu dobowym i tygodniowym,\n\u2022\tprojektowane rozwi\u0105zania powinny umo\u017cliwia\u0107 osi\u0105gni\u0119cie sprawno\u015bci ca\u0142kowitej systemu grzewczego na poziomie nie ni\u017cszym ni\u017c \u03b7 = 0,821, zgodnie z za\u0142o\u017ceniami audytu energetycznego.\nD. Modernizacj\u0119 systemu wentylacji:\n\u2022\tzastosowanie wentylacji mechanicznej z odzyskiem ciep\u0142a (rekuperacj\u0105) w cz\u0119\u015bci biurowej, \n\u2022\tminimalna sprawno\u015b\u0107 odzysku ciep\u0142a: 72%. \nE. Modernizacj\u0119 systemu klimatyzacji:\n\u2022\tzaprojektowanie scentralizowanego systemu klimatyzacji wraz z now\u0105 jednostk\u0105 wytw\u00f3rcz\u0105 \ni systemem dystrybucji powietrza. \nF. Modernizacj\u0119 instalacji elektrycznej i o\u015bwietlenia:\n\u2022\tzaprojektowanie wymiany instalacji elektrycznej dla ca\u0142ego obiektu, z uwzgl\u0119dnieniem wieku, stanu technicznego istniej\u0105cej instalacji oraz konieczno\u015bci ograniczenia strat energetycznych,\n\u2022\tzaprojektowanie nowej rozdzielni elektrycznej wraz z niezb\u0119dn\u0105 infrastruktur\u0105 techniczn\u0105,\n\u2022\tdostosowanie instalacji elektrycznej do projektowanych system\u00f3w wentylacji mechanicznej, klimatyzacji, o\u015bwietlenia oraz sufit\u00f3w podwieszanych,\n\u2022\twymiana opraw o\u015bwietleniowych na energooszcz\u0119dne oprawy LED.\nZamawiaj\u0105cy dopuszcza rozwi\u0105zania r\u00f3wnowa\u017cne spe\u0142niaj\u0105ce wymagane parametry techniczne \ni jako\u015bciowe.\n3.\tZakres dokumentacji projektowej\nWykonawca zobowi\u0105zany jest do opracowania:\n\u2022\tprojektu budowlanego, \n\u2022\tprojektu technicznego, \n\u2022\tprojektu wykonawczego, \n\u2022\tprzedmiaru rob\u00f3t, \n\u2022\tkosztorysu inwestorskiego, \n\u2022\tspecyfikacji technicznej wykonania i odbioru rob\u00f3t (STWiOR), \n\u2022\tuzyskania wszelkich wymaganych uzgodnie\u0144, opinii i sprawdze\u0144. \n4.\tWymagania dotycz\u0105ce dokumentacji\nDokumentacja projektowa musi by\u0107 opracowana w spos\u00f3b umo\u017cliwiaj\u0105cy:\n\u2022\tjednoznaczne okre\u015blenie zakresu rob\u00f3t budowlanych, \n\u2022\tprzygotowanie post\u0119powania na wyb\u00f3r wykonawcy rob\u00f3t, \n\u2022\tprawid\u0142ow\u0105 realizacj\u0119 inwestycji. \nDokumentacja musi zawiera\u0107 w szczeg\u00f3lno\u015bci:\n\u2022\tszczeg\u00f3\u0142owe rozwi\u0105zania materia\u0142owe i technologiczne, \n\u2022\trysunki wykonawcze oraz detale techniczne, \n\u2022\tobliczenia projektowe (w tym cieplne, energetyczne i instalacyjne), \n\u2022\tdob\u00f3r urz\u0105dze\u0144 i instalacji, \n\u2022\tzestawienia materia\u0142\u00f3w i urz\u0105dze\u0144, \n\u2022\twytyczne wykonawcze i monta\u017cowe. \n\nWykonawca zobowi\u0105zany b\u0119dzie do pe\u0142nienia nadzoru autorskiego nad opracowan\u0105 dokumentacj\u0105 projektow\u0105 na etapie realizacji inwestycji, na zasadach okre\u015blonych w Umowie.","warranty_period":"5 lat","cpv_items":[{"id":8079,"code":"71220000-6","name":"Us\u0142ugi projektowania architektonicznego"},{"id":8137,"code":"71320000-7","name":"Us\u0142ugi in\u017cynieryjne w zakresie projektowania"}],"timetable_items":[],"fulfillment_places":[{"country":"Polska","voivodeship":"kujawsko-pomorskie","poviat":"bydgoski","commune":"Osielsko","locality":"Osielsko","created_by":null,"created_at":"2026-06-24 15:55:55","modified_at":"2026-06-24 15:56:30","modified_by":null,"id":773988,"type":{"id":1,"name":"adres"},"group_uuid":"351aa812-7212-4328-a71b-4fac35623839"}],"participation_conditions":[{"id":1943879,"description":"Wykonawca dysponuje osobami posiadaj\u0105cymi uprawnienia budowlane do projektowania \nw specjalno\u015bciach: architektonicznej lub konstrukcyjno-budowlanej, instalacyjnej (sanitarnej) oraz instalacyjnej (elektrycznej) niezb\u0119dnym do realizacji Przedmiotu zam\u00f3wienia. Na etapie sk\u0142adania oferty Wykonawca zobowi\u0105zany jest przed\u0142o\u017cy\u0107 dokumenty potwierdzaj\u0105ce posiadanie wymaganych uprawnie\u0144 budowlanych przez osoby skierowane do realizacji zam\u00f3wienia oraz aktualne za\u015bwiadczenia o przynale\u017cno\u015bci do w\u0142a\u015bciwych izb samorz\u0105du zawodowego.","type":{"id":1,"name":"Uprawnienia do wykonywania okre\u015blonej dzia\u0142alno\u015bci lub czynno\u015bci"},"created_by":null,"created_at":"2026-06-24 15:55:55","modified_at":"2026-06-24 15:55:55","modified_by":null,"group_uuid":"08d3c1ab-eb9b-4fd9-a071-1b0119e8b113"},{"id":1943880,"description":"Aktualna polisa ubezpieczeniowa od odpowiedzialno\u015bci cywilnej w zakresie prowadzonej dzia\u0142alno\u015bci zwi\u0105zanej z Przedmiotem zam\u00f3wienia.","type":{"id":5,"name":"Sytuacja ekonomiczna i finansowa"},"created_by":null,"created_at":"2026-06-24 15:55:55","modified_at":"2026-06-24 15:55:55","modified_by":null,"group_uuid":"e54a23ec-599a-42e2-947f-440343757e03"},{"id":1943881,"description":"Za spe\u0142nienie kryterium uznaje si\u0119 wykonanie w okresie ostatnich trzech lat przed up\u0142ywem terminu sk\u0142adania ofert, a je\u017celi okres prowadzenia dzia\u0142alno\u015bci jest kr\u00f3tszy \u2013 w tym okresie, przynajmniej dw\u00f3ch us\u0142ug polegaj\u0105cych na wykonaniu projektu termomodernizacji lub modernizacji energetycznej budynk\u00f3w.","type":{"id":2,"name":"Wiedza i do\u015bwiadczenie"},"created_by":null,"created_at":"2026-06-24 15:55:55","modified_at":"2026-06-24 15:55:55","modified_by":null,"group_uuid":"10f12d71-ce49-42c3-9b82-8d7803697fb3"}],"category":{"id":2,"name":"Roboty budowlane"},"subcategory":{"id":9,"name":"Roboty budowlane"},"created_by":null,"created_at":"2026-06-24 15:55:55","modified_at":"2026-06-24 15:56:30","modified_by":null,"group_uuid":"be393bd9-85ea-4ab6-8cc5-7641acc07ff9"}],"evaluation_criteria":[{"id":1089414,"price_criterion":true,"description":"cena rycza\u0142towa netto za realizacj\u0119 Przedmiotu zam\u00f3wienia \u2013 95%","created_by":null,"created_at":"2026-06-24 15:55:55","modified_at":"2026-06-24 15:55:55","modified_by":null,"group_uuid":"dabce2ef-7716-4bd9-8ef8-a7e606742cb5"},{"id":1089415,"price_criterion":false,"description":"zatrudnienie os\u00f3b z grup marginalizowanych \u2013 5%","created_by":null,"created_at":"2026-06-24 15:55:55","modified_at":"2026-06-24 15:55:55","modified_by":null,"group_uuid":"57a3e5db-77d2-4320-912e-be2019690c3a"}],"is_variant":false,"title":"Wykonanie projektu termomodernizacji budynku biurowego","order_node":{"id":450306},"created_by":null,"created_at":"2026-06-24 15:55:55","modified_at":"2026-06-24 15:56:30","modified_by":null}],"created_by":{"id":120496,"contact_persons":[]},"modified_by":{"modified_by":null,"id":1,"contact_persons":[]},"status":{"id":2,"label":"PUBLISHED","name":"Opublikowane"},"advertiser_address_details":{"name":"Comtex Sp. z o.o. Sp. k.","identification_number_type":"nip","identification_number":"7123285104","address":{"country":"Polska","voivodeship":"lubelskie","poviat":"Lublin","commune":"Lublin","locality":"Lublin","created_by":{"id":120496,"contact_persons":[]},"created_at":"2026-06-24 15:55:55","modified_at":"2026-06-24 15:55:55","modified_by":{"id":120496,"contact_persons":[]},"id":1056775,"street":"Wojciechowska","number_description":"9A","postcode":"20-704"},"created_by":{"id":120496,"contact_persons":[]},"created_at":"2026-06-24 15:55:55","modified_at":"2026-06-24 15:55:55","modified_by":{"id":120496,"contact_persons":[]},"id":374892},"advertisement":{"id":279030,"number":"2026-120496-279030","publication_date":"2026-05-26","created_by":{"id":120496,"contact_persons":[]},"created_at":"2026-05-25 14:57:30","modified_at":"2026-06-30 00:00:24","modified_by":{"modified_by":null,"id":1,"contact_persons":[]},"status":{"id":6,"label":"RESOLVED","name":"Rozstrzygni\u0119te"},"all_available_version_ids":[368782,372945,373898],"enrollment":null,"projects":[{"id":71838,"name":"Poprawa efektywno\u015bci energetycznej w Comtex Sp. z o.o. Sp.k.","number":"1214/25","activity":{"created_by":{"modified_by":null,"id":89,"contact_persons":[]},"created_at":"2023-02-01 09:26:43","modified_at":"2023-02-01 09:26:43","modified_by":{"modified_by":null,"id":89,"contact_persons":[]}},"region":null,"institution":{"created_by":{"modified_by":null,"id":89,"contact_persons":[]},"created_at":"2023-02-01 09:28:57","modified_at":"2023-02-01 09:28:57","modified_by":{"modified_by":null,"id":89,"contact_persons":[]}},"full_number":"FENG.03.01-IP.03-1214/25","perspective":{},"programme":{"created_by":{"modified_by":null,"id":89,"contact_persons":[]},"created_at":"2023-02-01 09:21:41","modified_at":"2023-02-01 09:21:41","modified_by":{"modified_by":null,"id":89,"contact_persons":[]}},"priority":{"created_by":{"modified_by":null,"id":89,"contact_persons":[]},"created_at":"2023-02-01 09:22:08","modified_at":"2023-02-01 09:22:08","modified_by":{"modified_by":null,"id":89,"contact_persons":[]}},"type":"project","created_by":{"id":120496,"contact_persons":[]},"created_at":"2026-05-26 09:05:25","modified_at":"2026-05-26 09:05:25","modified_by":{"id":120496,"contact_persons":[]}}],"is_author":false,"is_admin":false},"attachments":[{"origin":{"id":368782,"publication_date":"2026-05-26"},"id":2552542,"name":"za\u0142. nr 1 - formularz oferty","file":{"id":2833368,"name":"Za\u0142\u0105cznik nr_1_Formularz_oferty.docx","created_at":"2026-06-24 15:55:55","created_by":{"forename":"\u0141ukasz","surname":"Bernatowicz"},"uri":"/api/files/2833368"},"group_uuid":"649c8eb5-700b-45e3-aadf-148eef1d94a4"},{"origin":{"id":368782,"publication_date":"2026-05-26"},"id":2552543,"name":"za\u0142. nr 2 - o\u015bwiadczenie wykonawcy \u2013 aspekty spo\u0142eczne","file":{"id":2833379,"name":"Za\u0142\u0105cznik nr_2_O\u015bwiadczenie Wykonawcy \u2013 aspekty spo\u0142eczne.docx","created_at":"2026-06-24 15:55:55","created_by":{"forename":"\u0141ukasz","surname":"Bernatowicz"},"uri":"/api/files/2833379"},"group_uuid":"07328504-bfb6-484d-a53e-1b74dc5a5d00"},{"origin":{"id":368782,"publication_date":"2026-05-26"},"id":2552544,"name":"za\u0142. nr 3 - wykaz us\u0142ug","file":{"id":2833388,"name":"Za\u0142\u0105cznik nr_3_Wykaz_us\u0142ug.docx","created_at":"2026-06-24 15:55:55","created_by":{"forename":"\u0141ukasz","surname":"Bernatowicz"},"uri":"/api/files/2833388"},"group_uuid":"8c000f3b-85e9-4222-ba15-ed50eac7b0ea"},{"origin":{"id":368782,"publication_date":"2026-05-26"},"id":2552545,"name":"za\u0142. nr 4 - o\u015bwiadczenie wykonawcy o powiazaniach","file":{"id":2833394,"name":"Za\u0142\u0105cznik nr_4_O\u015bwiadczenie_Wykonawcy_o_powiazaniach.docx","created_at":"2026-06-24 15:55:55","created_by":{"forename":"\u0141ukasz","surname":"Bernatowicz"},"uri":"/api/files/2833394"},"group_uuid":"376fc310-7cc5-44e7-85c2-416d458a8912"},{"origin":{"id":368782,"publication_date":"2026-05-26"},"id":2552546,"name":"za\u0142. nr 5 - wz\u00f3r umowy","file":{"id":2833923,"name":"Za\u0142\u0105cznik nr_5_Wz\u00f3r_umowy_Comtex.pdf","created_at":"2026-06-24 15:55:55","created_by":{"forename":"\u0141ukasz","surname":"Bernatowicz"},"uri":"/api/files/2833923"},"group_uuid":"626c547b-a1f3-43b0-9581-e8b9b78dcdcb"},{"origin":{"id":368782,"publication_date":"2026-05-26"},"id":2553001,"name":"za\u0142. nr 6 - potwierdzenie odbycia wizji lokalnej","file":{"id":2833925,"name":"Za\u0142\u0105cznik nr_6_Potwierdzenie odbycia wizji lokalnej.docx","created_at":"2026-06-24 15:55:55","created_by":{"forename":"\u0141ukasz","surname":"Bernatowicz"},"uri":"/api/files/2833925"},"group_uuid":"17ca2ff7-f573-4ee8-89ca-44842a44eb39"},{"origin":{"id":368782,"publication_date":"2026-05-26"},"id":2553002,"name":"zapytanie ofertowe","file":{"id":2833993,"name":"2026.05_Zapytanie_ofertowe_Comtex.pdf","created_at":"2026-06-24 15:55:55","created_by":{"forename":"\u0141ukasz","surname":"Bernatowicz"},"uri":"/api/files/2833993"},"group_uuid":"6fbcdd9a-be40-4c7c-bbcd-17506c068daf"},{"origin":{"id":372945,"publication_date":"2026-06-18"},"id":2600401,"name":"Aktualizacja zapytania ofertowego","file":{"id":2887111,"name":"Zapytanie ofertowe Comtex - aktualizacja-2.pdf","created_at":"2026-06-24 15:55:55","created_by":{"forename":"\u0141ukasz","surname":"Bernatowicz"},"uri":"/api/files/2887111"},"group_uuid":"ecebeca6-a58a-46c4-a3d5-cd939c0b090b"},{"origin":{"id":373898,"publication_date":"2026-06-24"},"id":2612055,"name":"Aktualizacja zapytania ofertowego-2","file":{"id":2899961,"name":"Zapytanie ofertowe Comtex - aktualizacja-3-1-2.pdf","created_at":"2026-06-24 15:55:39","created_by":{"forename":"\u0141ukasz","surname":"Bernatowicz"},"uri":"/api/files/2899961"},"group_uuid":"297f7d12-1503-4975-85ae-66839a1a0f15"}]},"dictionaries":{"announcement_status_draft":1,"announcement_status_published":2},"favorite":null,"badge":null,"offer_set_badge_count":null,"question_badge_count":null}}