{"status":"OK","data":{"advertisement":{"id":198677,"title":"Zabudowa urz\u0105dze\u0144 elektroenergetycznych w budynku stacji elektroenergetycznej 110/6 kV H-31 wraz z budow\u0105 linii elektroenergetycznych","partial_offer_allowed":false,"publication_date":"2023-03-23","submission_deadline":"2023-03-27 10:00:00","planned_sign_date":"2023-03-01","supplementary_orders":null,"terms_of_contract_change":"Zgodnie z projektem umowy \u00a7 21 ust. 21","created_at":"2023-03-23 13:25:48","modified_at":"2023-03-27 10:00:04","contact_persons":[{"id":15007,"forename":"Wojciech","surname":"Fryze\u0142","phone_number":"717943609","email":"wojciech.fryzel@pcc.eu","created_by":null,"created_at":"2023-04-18 11:19:10","modified_at":"2023-04-18 11:19:10","modified_by":null}],"orders":[{"id":328830,"estimated_value":null,"order_items":[{"id":373169,"description":"1.\tW zakresie realizacji zadania inwestycyjnego le\u017cy wykonanie nast\u0119puj\u0105cych prac: \na)\tdostaw\u0119 i monta\u017c urz\u0105dze\u0144 w budynku stacji elektroenergetycznej 110/6 kV H-31 uj\u0119tych w dokumentacji projektowej, dokumentacji o kt\u00f3rej mowa w pkt. g poni\u017cej oraz w za\u0142\u0105czniku nr 10 oraz monta\u017c urz\u0105dze\u0144 dostarczonych w ramach dostawy inwestorskiej,\nb)\tdostaw\u0119 i monta\u017c zabezpieczenia r\u00f3\u017cnicowopr\u0105dowego linii w polu nr 28 rozdzielni 6kV stacji F-3 wraz z rozbudow\u0105 uk\u0142adu telemechaniki SYNDIS RV w stacji F-3. Szczeg\u00f3\u0142owy zakres prac wskazano w Za\u0142\u0105czniku nr 9 do SIWZ.\nc)\tbudow\u0119 linii kablowych 110kV, 6kV, sterowniczych, sygnalizacyjnych i \u015bwiat\u0142owodowych zgodnie z Dokumentacj\u0105 Projektow\u0105 z wy\u0142\u0105czeniem budowy, okre\u015blonych w tomie L02/I (SDT 7006-08.00-02):\n- linii kablowych 6kV i kanalizacji \u015bwiat\u0142owodowej LO-3 w relacji H-31/G-22,\n- linii kablowych 6 kV w relacji H-31/H-19,\n- linii kablowych 6 kV w relacji H-31/H-58.\nd)\tbudow\u0119 i pod\u0142\u0105czenie linii kablowych relacji od stacji H-31 do od\u0142\u0105cznik\u00f3w liniowych w polach nr 4, 5, 16 i 18 RG 6kV w budynku H-26 (EC-2). \ne)\twprowadzenie 4 tor\u00f3w linii kablowych YHAKXS 6/10 1x240mm2 o oznaczeniu L453, L454, L455, L456, L457 do pola nr 5 RG 6kV w budynku H-26 (EC-2), \nf)\twykonanie ekspertyzy technicznej no\u015bno\u015bci stropu w budynku H-31 oraz analiz\u0119 pod k\u0105tem mo\u017cliwo\u015bci zabudowy zaproponowanej przez Wykonawc\u0119 rozdzielnicy 110 kV GIS i rozdzielnicy 6 kV. W przypadku zaistnienia konieczno\u015bci dostosowania konstrukcji budynku H-31 np. w zakresie zmiany otworowania lub wzmocnienia stropu wykonanie projektu wykonawczego zamiennego, na jego podstawie wykonanie wymaganych zmian w konstrukcji budynku oraz odtworzenie zastanego stanu pierwotnego. Rysunki pomieszczenia przeznaczonego do monta\u017cu rozdzielnic znajduj\u0105 si\u0119 dokumentacji projektowej nr SDT 7006-05.00-01 tom E01/I Obwody pierwotne oraz nr 7006-06.00-02 tom K01 Konstrukcja budynku stacyjnego stanowi\u0105cej Za\u0142\u0105cznik nr 8 do niniejszego SIWZ,\ng)\tprzeprojektowanie obwod\u00f3w pierwotnych i wt\u00f3rnych p\u00f3l nr 4 i 13 w zakresie szaf FR104 i FR113 oraz rozdzielnicy 110kV GIS w celu wyposa\u017cenia ich w uk\u0142ad do kontrolowanego synchronizowanego \u0142\u0105czenia biegun\u00f3w wy\u0142\u0105cznika. \nh)\tWykonanie projekt\u00f3w budowlanych zamiennych, uzgodnienie ich poprzez pozyskanie podpis\u00f3w na karcie KUD od w\u0142a\u015bciwych s\u0142u\u017cb PCC Rokita wraz z uzyskaniem wymaganych zamiennych pozwole\u0144 na budow\u0119 dla nast\u0119puj\u0105cych opracowa\u0144:\n\u2022\tProjekt Budowlany TOM BL2 nr SDT 7006-00.05-03 \u2013 zmiany powinny uwzgl\u0119dnia\u0107 wymagania zawarte w pkt. 2 i 3 poni\u017cszych Uwag,\n\u2022\tProjekt Budowlany TOM BL1-2 nr SDT 7006-00.05-01 \u2013 zmiany powinny uwzgl\u0119dnia\u0107 konieczno\u015b\u0107 dostosowania konstrukcji stropu budynku H-31.\ni)\twykonanie wszelkich wymaganych uzgodnie\u0144, potwierdzonych pisemnie z Tauron Dystrybucja S.A. w zakresie uruchomienia uk\u0142ad\u00f3w pomiarowych energii elektrycznej w rozdzielnicy 110kV, testowania automatyki EAZ (uwsp\u00f3\u0142bie\u017cnienie, odwzorowanie zadzia\u0142ania w systemie nadrz\u0119dnym) oraz wykonania wszelkich wymaganych pomiar\u00f3w pomonta\u017cowych umo\u017cliwiaj\u0105cych podanie napi\u0119cia w polach linii zasilaj\u0105cej nale\u017c\u0105cej do Tauron Dystrybucja S.A. \nj)\trealizacja inwestycji z uwzgl\u0119dnieniem postanowie\u0144 zawartych w warunkach przy\u0142\u0105czenia nr WP/049373/2018/O05R02 z dnia 29-10-2018r. oraz pismem nr PP/002/049373/2018/O05R02 z dnia 25-1-2019r. stanowi\u0105cych za\u0142\u0105cznik nr 4 do niniejszej SIWZ. \nk)\trozbudowa uk\u0142adu telemechaniki SYNDIS RV dla p\u00f3l nr 16 i 18 w RG 6kV EC-2 (H-26). Zakres prac zosta\u0142 uj\u0119ty w Za\u0142\u0105czniku nr 9 do niniejszej SIWZ.\nl)\tdemonta\u017c w budynku H-26 baterii kondensator\u00f3w oraz szaf regulacyjnych; \nm)\ttransport oraz monta\u017c i pod\u0142\u0105czenie do rozdzielnicy 6kV w budynku H-31 baterii kondensator\u00f3w oraz szaf regulacyjnych (szczeg\u00f3\u0142y dotycz\u0105ce monta\u017cu zawarto w opracowaniu Tom E01/I nr SDT 7006-05.00-01),\nn)\tw odniesieniu do pkt. 2.8 dokumentacji projektowej Tom L02/I nr SDT 7008-08.00-02 nale\u017cy wykona\u0107 przebudow\u0119 instalacji wod-kan przy budynku H-26. Zakres opracowania i wymagania techniczne zosta\u0142y uj\u0119te w Za\u0142\u0105czniku nr 10 do niniejszej SIWZ.\no)\twykonanie przy\u0142\u0105czy transformator\u00f3w T-3 i T-4 25MVA 110/6 kV do rozdzielnicy 110kV GIS, rozdzielnicy 6kV, instalacji uziemiaj\u0105cej oraz do szafy FTR101, \np)\twykonanie wszelkich obowi\u0105zk\u00f3w wynikaj\u0105cych z projektu umowy (w szczeg\u00f3lno\u015bci wskazane w \u00a7 2 ust. 1 lit. l) \u2013 z) stanowi\u0105cego za\u0142\u0105cznik nr 5 do niniejszej SIWZ.\nUwagi: \n1)\tW odniesieniu do dokumentacji nr SDT 7006-05.00-01 Obwody pierwotne, Tom E01/III - Kosztorys, Zamawiaj\u0105cy informuje, \u017ce wycenie nie podlegaj\u0105:\na.\tpozycja 3 z Dzia\u0142u nr 1 (dostawa transformatora 110/6 kV 25MVA, ilo\u015b\u0107 2 szt.) \u2013 dostawa inwestorska Zamawiaj\u0105cego (za\u0142\u0105cznik nr 17 do projektu umowy),\nb.\tpozycja 9-9* z Dzia\u0142u nr 1 (Kabel XnRUHKXS 1x150/50 64/110 kV) \u2013 dostawy inwestorskie Zamawiaj\u0105cego (za\u0142\u0105cznik nr 17 do projektu umowy),\nc.\tpozycja 15 z Dzia\u0142u nr 3 (dostawa transformatora 250kVA, ilo\u015b\u0107 2 szt.) \u2013 dostawa inwestorska Zamawiaj\u0105cego (za\u0142\u0105cznik nr 17 do projektu umowy),\nd.\tDzia\u0142 nr 5 (Instalacja uziemiaj\u0105ca stacji),\ne.\tDzia\u0142 nr 6 (Instalacja odgromowa),\nf.\tDzia\u0142 nr 7 (sprz\u0119t BHP), \ng.\tDzia\u0142 nr 8 (Tablice i znaki bezpiecze\u0144stwa),\nh.\t pozycje nr 60-2* i 60-3* z Dzia\u0142u 11 (Przepusty kablowe). \n2)\tW odniesieniu do dokumentacji nr SDT 7006-08.00-02 Przebudowa linii kablowych SN, Tom L02/III - Kosztorys, Zamawiaj\u0105cy informuje, \u017ce wycenie nie podlegaj\u0105:\na.\tDzia\u0142 nr 1 - Budowa linii kablowych 6kV i kanalizacji \u015bwiat\u0142owodowej LO-3 w relacji H-31/G-22,\nb.\tDzia\u0142 nr 5 - Budowa linii kablowych 6 kV w relacji H-31/H-19,\nc.\tDzia\u0142 nr 7 - Budowa linii kablowych 6 kV w relacji H-31/H-58, \n3)\tW odniesieniu do dokumentacji nr SDT 7006-08.00-02 Przebudowa linii kablowych SN, Tom L02/III - Kosztorys, Zamawiaj\u0105cy informuje, \u017ce:\na.\tPoz. nr 7* w Dziale nr 2.1.8. - Kabel YHKXS 6/10 1x300mm2 \u2013 nie podlega wycenie,\nb.\t Do wyceny prac w Dziale 2.1 (za wyj\u0105tkiem 2.1.8 poz.7*) nale\u017cy przyj\u0105\u0107 nast\u0119puj\u0105ce za\u0142o\u017cenia:\n\uf02d\t zmianie ulega typ i przekr\u00f3j kabla z YHKXS 6/10 1x300mm2 na YHAKXS 6/10 1x240mm2,\n\uf02d\tzmianie ulega liczba tor\u00f3w pr\u0105dowych z 5 na 4,\n\uf02d\tzmianie ulega miejsce przy\u0142\u0105czenia kabli w rozdzielni 6kV budynku H-26 \u2013 pierwotne miejsce wpi\u0119cia pole nr 7 zmieniono do pola nr 5 (Tomie L02/I, rys. nr 7006-08.00-0210).\n4)\tW odniesieniu do dokumentacji nr SDT 7006-05.00-03 Obwody wt\u00f3rne rozdzielni g\u0142\u00f3wnej 6kV, Tom E03/III - Kosztorys, Zamawiaj\u0105cy informuje, \u017ce:\na.\tw Dziale 24 pozycja 356-4*, w przypadku zastosowania innych terminali zabezpieczeniowych ni\u017c te uj\u0119te w projekcie, do wyceny nale\u017cy przyj\u0105\u0107 4 sztuki zabezpieczania r\u00f3\u017cnicowego linii dla p\u00f3l nr 11, 12, 27 i 28 w stacji F-3, wraz z monta\u017cem i rozbudow\u0105 uk\u0142adu telemechaniki SYNDIS RV w stacji F-3 (zakres prac zosta\u0142 uj\u0119ty w Za\u0142\u0105czniku nr 9 do niniejszej SIWZ).\n5)\tW odniesieniu do dokumentacji nr SDT 7006-08.00-01 Budowa linii kablowych 110 kV, Tom L01/III - Kosztorys, Zamawiaj\u0105cy informuje, \u017ce:\na.\tW Dziale nr 1 , poz. nr 1.1.7 - Budowa linii nr Sk-130a - nale\u017cy przyj\u0105\u0107 obmiar r\u00f3wny 300 mb, \nb.\tDzia\u0142 nr 1.2.1 , poz. nr 5* oraz Dzia\u0142 nr 1.2.2 , poz. nr 9* - kabel XnRUHKXS 1x800RMC/120 mm2 64/110kV - nie podlega wycenie \u2013 dostawa inwestorska Zamawiaj\u0105cego (za\u0142\u0105cznik nr 17 do projektu umowy),\nc.\tDzia\u0142 nr 1.2.10 , poz. nr 2* - kabel LgYcyw 1x185 mm2 3,6/6kV - nie podlega wycenie \u2013 dostawa inwestorska Zamawiaj\u0105cego (za\u0142\u0105cznik nr 17 do projektu umowy). \n6)\tW odniesieniu do dokumentacji nr SDT 7006-05.00-01, Tom E01/I (Obwody pierwotne) i E01/VI (Obwody pierwotne \u2013 Specyfikacja rozdzielnicy 6kV), Zamawiaj\u0105cy informuje, i\u017c ulegaj\u0105 zmianie parametry techniczne rozdzielnicy 6kV w zakresie pr\u0105d\u00f3w znamionowych ci\u0105g\u0142ych dotycz\u0105cych oszynowania, przek\u0142adnik\u00f3w pr\u0105dowych, od\u0142\u0105cznik\u00f3w i wy\u0142\u0105cznik\u00f3w dla:\na.\tSzyn zbiorczych system\u00f3w 1 i 2 (w tym nadstawka z od\u0142\u0105cznikiem) z 3150 A na 2500 A,\nb.\tP\u00f3l sprz\u0119g\u0142owych (pola nr 14, 16-17, 19) z 3150 A na 2500 A ,\nc.\tP\u00f3l zasilaj\u0105cych transformatorowych (pola nr 1 i 34) z 3150 A na 2500 A,\nd.\tPo\u0142 zasilaj\u0105cych generatorowych (pola nr 11 i 22) z 3150 A na 2500 A.\nPozosta\u0142e parametry techniczne rozdzielnicy pozostaj\u0105 bez zmian.\nWobec powy\u017cszego, w wycenie dzia\u0142u nr 2 Tomu E01/II- Kosztorys (Rozdzielnia 6 kV - obwody pierwotne) nale\u017cy uwzgl\u0119dni\u0107 rozdzielnic\u0119 6kV o zmienionych, jak wy\u017cej, parametrach technicznych.\n7)\tW odniesieniu do dokumentacji nr SDT 7006-06.00-03 Konstrukcje wsporcze aparat\u00f3w i urz\u0105dze\u0144, Tom K02/III - Kosztorys, Zamawiaj\u0105cy informuje, \u017ce wycenie nie podlegaj\u0105:\na.\tDzia\u0142 nr 6 (Podkonstrukcja misy olejowej),\nb.\tDzia\u0142 nr 7 (Kotwa)\nc.\tDzia\u0142 nr 8 (Nak\u0142adka do fundamentu).","warranty_period":"60 miesi\u0119cy","cpv_items":[{"id":6402,"code":"45200000-9","name":"Roboty budowlane w zakresie wznoszenia kompletnych obiekt\u00f3w budowlanych lub ich cz\u0119\u015bci oraz roboty w zakresie in\u017cynierii l\u0105dowej i wodnej"},{"id":6647,"code":"45230000-8","name":"Roboty budowlane w zakresie budowy ruroci\u0105g\u00f3w, linii komunikacyjnych i elektroenergetycznych, autostrad, dr\u00f3g, lotnisk i kolei"},{"id":7017,"code":"45310000-3","name":"Roboty instalacyjne elektryczne"}],"timetable_items":[],"fulfillment_places":[{"country":"Polska","voivodeship":"dolno\u015bl\u0105skie","poviat":"wo\u0142owski","commune":"Brzeg Dolny","locality":"Brzeg Dolny","created_by":null,"created_at":"2023-03-23 13:25:48","modified_at":"2023-03-23 13:25:48","modified_by":null,"id":420349,"type":{"id":1,"name":"adres"},"group_uuid":"98f2ac68-77da-4f3e-9e37-1e1457af6d75"}],"participation_conditions":[{"id":1014900,"description":"Oferent znajduje si\u0119 w sytuacji ekonomicznej i finansowej zapewniaj\u0105cej wykonanie zam\u00f3wienia","type":{"id":5,"name":"Sytuacja ekonomiczna i finansowa"},"created_by":null,"created_at":"2023-03-23 13:25:48","modified_at":"2023-03-23 13:25:48","modified_by":null,"group_uuid":"3881c428-75b3-4d5c-8b4f-814a869c4497"},{"id":1014901,"description":"Oferent wyka\u017ce si\u0119, \u017ce dysponuje:\na.\treferencjami potwierdzaj\u0105cymi spe\u0142nienie warunku okre\u015blonego w za\u0142\u0105czniku nr 2a do SIWZ,\nb.\twykazem zainstalowanych urz\u0105dze\u0144 spe\u0142niaj\u0105cych warunek okre\u015blony w za\u0142\u0105czniku nr 2b do SIWZ,\nc.\treferencjami potwierdzaj\u0105cymi spe\u0142nienie warunku okre\u015blonego w za\u0142\u0105czniku nr 2c do SIWZ,","type":{"id":2,"name":"Wiedza i do\u015bwiadczenie"},"created_by":null,"created_at":"2023-03-23 13:25:48","modified_at":"2023-03-23 13:25:48","modified_by":null,"group_uuid":"6da08572-c3da-4b10-b5ff-8d4aa1b18f46"},{"id":1014902,"description":"Oferent jest uprawniony do wyst\u0119powania w obrocie prawnym na terenie Rzeczpospolitej Polskiej.\nOferent posiada uprawnienia niezb\u0119dne do wykonania prac i czynno\u015bci b\u0119d\u0105cych przedmiotem zam\u00f3wienia.","type":{"id":1,"name":"Uprawnienia do wykonywania okre\u015blonej dzia\u0142alno\u015bci lub czynno\u015bci"},"created_by":null,"created_at":"2023-03-23 13:25:48","modified_at":"2023-03-23 13:25:48","modified_by":null,"group_uuid":"cc854b29-4e61-45c2-ba15-0a2f79703aed"},{"id":1014903,"description":"Wymagania opisano w punkcie V SIWZ Warunki wymagane od Oferent\u00f3w","type":{"id":7,"name":"Dodatkowe warunki udzia\u0142u"},"created_by":null,"created_at":"2023-03-23 13:25:48","modified_at":"2023-03-23 13:25:48","modified_by":null,"group_uuid":"10e9663e-020a-4c78-ac6d-a32741bb965d"}],"category":{"id":2,"name":"Roboty budowlane"},"subcategory":{"id":9,"name":"Roboty budowlane"},"created_by":null,"created_at":"2023-03-23 13:25:48","modified_at":"2023-03-23 13:25:48","modified_by":null,"group_uuid":"92acd3a3-6e5a-4460-85ce-dd9bd7cb3759"}],"evaluation_criteria":[{"id":571603,"price_criterion":true,"description":"Niezmiennym przez ca\u0142y czas post\u0119powania kryterium oceny ofert b\u0119dzie cena: 100 %","created_by":null,"created_at":"2023-03-23 13:25:48","modified_at":"2023-03-23 13:25:48","modified_by":null,"group_uuid":"3e41b8c4-f496-41b1-9e12-c514e70b4bce"}],"is_variant":false,"title":"Zabudowa urz\u0105dze\u0144 elektroenerg. w bud. stacji 110/6 kV H-31","order_node":{"id":238514},"created_by":null,"created_at":"2023-03-23 13:25:48","modified_at":"2023-03-23 13:25:48","modified_by":null}],"created_by":{"id":450,"contact_persons":[]},"modified_by":{"modified_by":null,"id":1,"contact_persons":[]},"status":{"id":2,"label":"PUBLISHED","name":"Opublikowane"},"advertiser_address_details":{"name":"PCC Rokita S.A.","identification_number_type":"nip","identification_number":"9170000015","address":{"country":"Polska","voivodeship":"dolno\u015bl\u0105skie","poviat":"wo\u0142owski","commune":"Brzeg Dolny","locality":"Brzeg Dolny","created_by":{"id":450,"contact_persons":[]},"created_at":"2023-03-23 13:25:48","modified_at":"2023-03-23 13:25:48","modified_by":{"id":450,"contact_persons":[]},"id":516840,"street":"Sienkiewicza ","number_description":"4","postcode":"56-120"},"created_by":{"id":450,"contact_persons":[]},"created_at":"2023-03-23 13:25:48","modified_at":"2023-03-23 13:25:48","modified_by":{"id":450,"contact_persons":[]},"id":199126},"advertisement":{"id":144252,"number":"2023-450-144252","publication_date":"2023-01-27","created_by":{"id":450,"contact_persons":[]},"created_at":"2023-01-27 12:28:45","modified_at":"2023-03-27 10:00:04","modified_by":{"modified_by":null,"id":1,"contact_persons":[]},"status":{"id":6,"label":"RESOLVED","name":"Rozstrzygni\u0119te"},"all_available_version_ids":[188714,192834,194168,195960,196982,198677],"enrollment":null,"projects":[{"id":392,"name":"Budowa stacji 110 kV w technologii GIS (H-31)","number":"0004/18","activity":{"created_by":{"modified_by":null,"id":1,"contact_persons":[]},"created_at":"2020-08-17 19:00:00","modified_at":"2020-08-17 19:00:00","modified_by":{"modified_by":null,"id":1,"contact_persons":[]}},"region":{"created_by":{"modified_by":null,"id":1,"contact_persons":[]},"created_at":"2022-02-10 21:45:42","modified_at":"2022-02-10 21:45:42","modified_by":{"modified_by":null,"id":1,"contact_persons":[]}},"institution":null,"full_number":"POIS.07.01.00-00-0004/18","perspective":{},"programme":{"created_by":{"modified_by":null,"id":1,"contact_persons":[]},"created_at":"2020-08-17 19:00:00","modified_at":"2020-08-17 19:00:00","modified_by":{"modified_by":null,"id":1,"contact_persons":[]}},"priority":{"created_by":{"modified_by":null,"id":1,"contact_persons":[]},"created_at":"2020-08-17 19:00:00","modified_at":"2020-08-17 19:00:00","modified_by":{"modified_by":null,"id":1,"contact_persons":[]}},"type":"project","created_by":{"id":450,"contact_persons":[]},"created_at":"2020-08-18 16:10:15","modified_at":"2020-08-18 16:10:15","modified_by":{"id":450,"contact_persons":[]}}],"is_author":false,"is_admin":false},"attachments":[{"origin":{"id":188714,"publication_date":"2023-01-27"},"id":890152,"name":"SIWZ","file":{"id":992836,"name":"SIWZ.pdf","created_at":"2023-03-23 13:25:48","created_by":{"forename":"PCC ROKITA SA","surname":"-"},"uri":"/api/files/992836"},"group_uuid":"1343f03e-bd32-464b-bc15-857144a29e18"},{"origin":{"id":188714,"publication_date":"2023-01-27"},"id":890338,"name":"Za\u0142\u0105czniki nr 2a - 12 do SIWZ","file":{"id":993065,"name":"Za\u0142\u0105czniki 2a-12 do SIWZ.zip","created_at":"2023-03-23 13:25:48","created_by":{"forename":"PCC ROKITA SA","surname":"-"},"uri":"/api/files/993065"},"group_uuid":"93a315bb-8020-44bf-a457-3942d5bb21b3"},{"origin":{"id":192834,"publication_date":"2023-02-20"},"id":915018,"name":"SIWZ rew 1","file":{"id":1020455,"name":"SIWZ_rew1.pdf","created_at":"2023-03-23 13:25:48","created_by":{"forename":"PCC ROKITA SA","surname":"-"},"uri":"/api/files/1020455"},"group_uuid":"30c09094-3260-45f0-a7d0-d4d4b3c3e218"},{"origin":{"id":192834,"publication_date":"2023-02-20"},"id":915019,"name":"Rewizja za\u0142\u0105cznik\u00f3w 1, 5, 11 i 12 oraz nowy za\u0142\u0105cznik nr 2d","file":{"id":1020456,"name":"Za\u0142\u0105czniki_rewizje_za\u0142_1_5_11_12_nowy_za\u0142_2d.zip","created_at":"2023-03-23 13:25:48","created_by":{"forename":"PCC ROKITA SA","surname":"-"},"uri":"/api/files/1020456"},"group_uuid":"659361cd-a29e-49f1-803a-5de6da98ff5d"},{"origin":{"id":192834,"publication_date":"2023-02-20"},"id":915020,"name":"Odpowiedzi na pytania oferent\u00f3w nr 1","file":{"id":1020457,"name":"Odpowiedzi na pytania oferent\u00f3w nr 1.pdf","created_at":"2023-03-23 13:25:48","created_by":{"forename":"PCC ROKITA SA","surname":"-"},"uri":"/api/files/1020457"},"group_uuid":"3e91c226-82de-478e-907f-f1334126a9e5"},{"origin":{"id":194168,"publication_date":"2023-02-28"},"id":923926,"name":"Odpowiedzi na pytania oferent\u00f3w nr 2","file":{"id":1030321,"name":"Odpowiedzi na pytania oferent\u00f3w nr 2.pdf","created_at":"2023-03-23 13:25:48","created_by":{"forename":"PCC ROKITA SA","surname":"-"},"uri":"/api/files/1030321"},"group_uuid":"d94a8fb2-08c6-4390-82a4-6790e491c210"},{"origin":{"id":194168,"publication_date":"2023-02-28"},"id":923927,"name":"Rewizja za\u0142\u0105cznik\u00f3w nr 2a, 2d, 5, 7, 11.","file":{"id":1030323,"name":"Za\u0142\u0105czniki_rewizje_za\u0142_2a_2d_5_7_11.zip","created_at":"2023-03-23 13:25:48","created_by":{"forename":"PCC ROKITA SA","surname":"-"},"uri":"/api/files/1030323"},"group_uuid":"ace7acc0-7d69-45b6-a6eb-fae9744b0c18"},{"origin":{"id":195960,"publication_date":"2023-03-09"},"id":934771,"name":"Rewizja za\u0142\u0105cznik\u00f3w nr 5 i 11","file":{"id":1042382,"name":"Za\u0142\u0105czniki_rewizje_za\u0142_5_11.zip","created_at":"2023-03-23 13:25:48","created_by":{"forename":"PCC ROKITA SA","surname":"-"},"uri":"/api/files/1042382"},"group_uuid":"cbf37dab-27cc-4bd1-91c9-ceb0e0498444"},{"origin":{"id":195960,"publication_date":"2023-03-09"},"id":934772,"name":"SIWZ rew 2","file":{"id":1042384,"name":"SIWZ_rew2.pdf","created_at":"2023-03-23 13:25:48","created_by":{"forename":"PCC ROKITA SA","surname":"-"},"uri":"/api/files/1042384"},"group_uuid":"972cb88b-2a4f-4fc6-ac2e-664dafcba8ec"},{"origin":{"id":195960,"publication_date":"2023-03-09"},"id":934773,"name":"Odpowiedzi na pytania oferent\u00f3w nr 3","file":{"id":1042387,"name":"Odpowiedzi na pytania oferent\u00f3w nr 3.pdf","created_at":"2023-03-23 13:25:48","created_by":{"forename":"PCC ROKITA SA","surname":"-"},"uri":"/api/files/1042387"},"group_uuid":"682aa62a-f88a-4129-b2ed-3a48dfe4fa08"},{"origin":{"id":196982,"publication_date":"2023-03-15"},"id":940672,"name":"Odpowiedzi na pytania oferent\u00f3w nr 4","file":{"id":1048863,"name":"Odpowiedzi na pytania oferent\u00f3w nr 4.pdf","created_at":"2023-03-23 13:25:48","created_by":{"forename":"PCC ROKITA SA","surname":"-"},"uri":"/api/files/1048863"},"group_uuid":"27254e6c-142a-47d4-87ab-210853f221b0"},{"origin":{"id":198677,"publication_date":"2023-03-23"},"id":951125,"name":"Odpowiedzi na pytania oferent\u00f3w nr 5","file":{"id":1060339,"name":"Odpowiedzi na pytania oferent\u00f3w nr 5.pdf","created_at":"2023-03-23 13:23:56","created_by":{"forename":"PCC ROKITA SA","surname":"-"},"uri":"/api/files/1060339"},"group_uuid":"5429a88c-4ab8-426b-a8ca-b10030ba55e5"},{"origin":{"id":198677,"publication_date":"2023-03-23"},"id":951126,"name":"Odpowiedzi na pytania oferent\u00f3w nr 6","file":{"id":1060340,"name":"Odpowiedzi na pytania oferent\u00f3w nr 6.pdf","created_at":"2023-03-23 13:24:04","created_by":{"forename":"PCC ROKITA SA","surname":"-"},"uri":"/api/files/1060340"},"group_uuid":"783ba32a-2e84-4d98-a4c9-4d4b4ad18446"},{"origin":{"id":198677,"publication_date":"2023-03-23"},"id":951127,"name":"Rewizja nr 4 za\u0142\u0105cznika nr 5 do SIWZ","file":{"id":1060341,"name":"Za\u0142 5_Projekt_umowy_rew4.pdf","created_at":"2023-03-23 13:24:21","created_by":{"forename":"PCC ROKITA SA","surname":"-"},"uri":"/api/files/1060341"},"group_uuid":"892b2fb8-87db-4232-a040-90be5552fc68"},{"origin":{"id":198677,"publication_date":"2023-03-23"},"id":951128,"name":"Rewizja nr 5 za\u0142\u0105cznika nr 5 do SIWZ","file":{"id":1060342,"name":"Za\u0142 5_Projekt_umowy_rew5.pdf","created_at":"2023-03-23 13:25:01","created_by":{"forename":"PCC ROKITA SA","surname":"-"},"uri":"/api/files/1060342"},"group_uuid":"9625953a-3d23-4155-b101-09cc84f802a2"},{"origin":{"id":198677,"publication_date":"2023-03-23"},"id":951129,"name":"SIWZ rew nr 3","file":{"id":1060343,"name":"SIWZ_rew3.pdf","created_at":"2023-03-23 13:25:33","created_by":{"forename":"PCC ROKITA SA","surname":"-"},"uri":"/api/files/1060343"},"group_uuid":"95959a52-de8b-481f-b7b9-72e84e068acd"}]},"dictionaries":{"announcement_status_draft":1,"announcement_status_published":2},"favorite":null,"badge":null,"offer_set_badge_count":null,"question_badge_count":null}}